SKU | HI9829-02-web |
---|
Product Name | HI9829 Multiparameter pH/ISE/EC/DO/Turbidity Waterproof Meter with GPS option |
---|
Quote Required | Yes |
---|
pH Range | 0.00 to 14.00 pH |
---|
pH Resolution | 0.01 pH |
---|
pH Accuracy | ±0.02 pH |
---|
pH Calibration | automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer |
---|
ORP Range | ±2000 mV |
---|
ORP Resolution | 0.1 mV |
---|
ORP Accuracy | ±1.0 mV |
---|
ORP Calibration | automatic at one custom point (relative mV) |
---|
mV Range | ±600.0 mV |
---|
mV Resolution | 0.1 mV |
---|
mV Accuracy | ±0.5 mV |
---|
EC Range | 0 to 200 mS/cm (absolute EC up to 400 mS/cm) |
---|
EC Resolution | Manual |
---|
EC Accuracy | ±1% of reading or ±1 µS/cm whichever is greater |
---|
EC Calibration | automatic single point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point |
---|
TDS Range | 0 to 400000 ppm (mg/L); (the maximum value depends on the TDS factor) |
---|
TDS Resolution | Manual |
---|
TDS Accuracy | ±1% of reading or ±1 ppm (mg/L), whichever is greater |
---|
TDS Calibration | based on conductivity or salinity calibration |
---|
Salinity (PSU) Range | 0.00 to 70.00 PSU |
---|
Salinity (PSU) Resolution | 0.01 PSU |
---|
Salinity (PSU) Accuracy | ±2% of reading or ±0.01 PSU whichever is greater |
---|
Salinity (PSU) Calibration | based on conductivity calibration |
---|
Salinity (Seawater Sigma) Range | 0.0 to 50.0 σt, σ₀, σ₁₅ |
---|
Salinity (Seawater Sigma) Resolution | 0.1 σt, σ₀, σ₁₅ |
---|
Salinity (Seawater Sigma) Accuracy | ±1 σt, σ₀, σ₁₅ |
---|
Salinity (Seawater Sigma) Calibration | based on conductivity or salinity calibration |
---|
Resistivity Range | 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm |
---|
Resistivity Resolution | dependent on resistivity reading |
---|
Resistivity Calibration | based on conductivity calibration |
---|
Dissolved Oxygen Range | 0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L) |
---|
Dissolved Oxygen Resolution | 0.1%; 0.01 ppm (mg/L) |
---|
Dissolved Oxygen Accuracy | 0.0 to 300.0% saturation |
---|
Dissolved Oxygen Calibration | automatic one or two points at 0 and 100% or one custom point |
---|
Turbidity Range | 0.0 to 99.9 FNU; 100 to 1000 FNU |
---|
Turbidity Resolution | 0.1 FNU from 0.0 to 99.9 FNU 1 FNU from 100 to 1000 FNU |
---|
Turbidity Accuracy | ±0.3 FNU or ±2 % of reading, whichever is greater |
---|
Turbidity Calibration | Automatic 1, 2, or, 3 points at 0, 20 and 200 FNU, or custom |
---|
Temperature Range | -5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K |
---|
Temperature Resolution | 0.01 K, 0.01 °C, 0.01 °F |
---|
Temperature Accuracy | ±0.15 °C; ±0.27 °F; ±0.15 K |
---|
Temperature Calibration | automatic at one custom point |
---|
Temperature Compensation | automatic from -5 to 55 °C (23 to 131 °F) |
---|
Ammonium Range | 0.02 to 200.0 ppm (as NH4+-N) |
---|
Ammonium Resolution | 0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm |
---|
Ammonium Accuracy | ±5 % reading or 2 ppm |
---|
Ammonium Calibration | 1 or 2 point, 10 ppm and 100 ppm |
---|
Chloride Range | 0.6 to 200.0 ppm Cl (as Cl- ) |
---|
Chloride Resolution | 0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm |
---|
Chloride Accuracy | ±5 % of reading or 2 ppm |
---|
Chloride Calibration | 1 or 2 point, 10 ppm and 100 ppm |
---|
Nitrate Range | 0.62 to 200.0 ppm Ni (as NO3 - -N) |
---|
Nitrate Resolution | 0.01 ppm to 1 ppm 0.1 ppm to 200 ppm |
---|
Nitrate Calibration | 1 or 2 point, 10 ppm and 100 ppm |
---|
Logging Memory | 44,000 records (continuous logging or log-on-demand of all parameters) |
---|
Logging Interval | one second to three hours |
---|
Connectivity | USB (with HI 929829 software) |
---|
Battery Type/Life | 1.2V (4) NiMH, rechargeable batteries, size C type; up to 140 hours depending on configuration |
---|
IP Protection | IP67 |
---|
Environment | 0 to 50°C (32 to 122°F); RH max 100% |
---|
Dimensions | 221 x 115 x 55 mm (8.7 x 4.5 x 2.2”) |
---|
Weight | 750 g (26.5 oz.) |
---|
GPS | 12 channel receiver 10 m (30 ft) accuracy |
---|
Ordering Information | The HI9829 and HI98290 (GPS model) are supplied with a HI710140 hard carrying case, HI7612VDC adapter, HI7698292 probe maintenance kit, HI929829 PC application software, HI7698291 USB cable (PC to meter), HI710045 power supply cable, HI710046 cigarette lighter power cable, HI9829-25 quick calibration solution, HI920005 iButton with holder (5), HI7609829-1 pH/ORP sensor, HI7609829-2 galvanic DO sensor, HI7609829-3 EC sensor, HI7698290 short calibration beaker, HI7698295 short protective weighted shield, NiMH rechargeable “C” cell batteries (4), 12VDC power adapter, and instruction manual. |
---|
Atmospheric Pressure Range | 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa |
---|
Atmospheric Pressure Resolution | 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa |
---|
Atmospheric Pressure Accuracy | ±3 mm Hg within ±15% from calibration point |
---|
Atmospheric Pressure Calibration | automatic at one custom point |
---|